横截面积测量仪示值误差测量结果不确定度评定
Evaluation of Uncertainty of Measurement Result in Indication Error of Cross-Section Measuring Device
-
摘要: 使用四等量块校准型号CMU的横截面积测量仪的系统示值,参照《测量不确定度评定与表示》(JJF 1059.1-2012)计量技术规范,分析了系统示值结果不确定度的来源,并进行了综合评定。Abstract: The system indication values of CMU cross-section measuring device is calibrated by the gauge blocks of grade four. Referring to the measurement technical specification of Evaluation and Expression of Uncertainty in Measurement( JJF1059. 1-2012),the source of uncertainty of indication result of the system is analyzed and comprehensively evaluated.