Abstract:
In this paper,a modal parameter identification algorithm of time-varying system based on chirp-Z transformation is proposed. The frequency response characteristics of the structure with refined frequency are obtained by chirp-Z transformation,and then the modal parameters are obtained by modal parameter identification algorithm. The method is verified by three degree of freedom system. Finally,the dynamic characteristic parameters of the heated wing structure are identified,which provides a method for hypersonic thermal modal test.