Abstract:
In order to improve the efficiency and accuracy of the total nitrogen and phosphorus content deteceion in biogas slurry,the samples of biogas slurry were digested by graphite digester and the content of nitrogen and phosphorus in biogas slurry was determined by continuous flow injection analyzer.The accuracy,precision,detection limit and quantitative limit of the method were studied.The results showed that the average recoveries of nitrogen and phosphorus were 96.75%-104.50% and 100.82%-101.47%,respectively.The results showed good repeatability and reproducibility.The detection limit of total nitrogen was 10 mg·L
-1,the quantitative limit was 30 mg·L
-1,the detection limit of total phosphorus was 4 mg·L
-1 the quantitative limit was 12 mg·L
-1.This method can be used for rapid and efficient determination of total nitrogen and total phosphorus in biogas slurry.