松节油精馏塔温度灵敏板的确定
Location of Temperature-sensitive Plates in Turpentine Distillation Tower
-
摘要: 利用Peng Rob算法,分别研究了稳态和动态扰动条件下松节油双塔连续精馏中,各精馏塔温度灵敏板的位置,结果表明不同方法确定的低沸塔灵敏板差异在3块板范围之内,高沸塔的灵敏板在第16块板。在此基础上可适时调整可操控变量,使灵敏塔板温度保持恒定,保证蒸馏效率和产品质量。Abstract: The location of temperative-sensitive plates in the turpentine dual-tower continuous distillation system under both static and dynamic conditions was determined using Peng Rob method. The result shows that the location of sensitive plates of low-boiling-point column varies within three plates, while the No.16th plate is the sensitive one in high-boiling-point column. Based on this study, the parameters can be promptly adjusted to keep the stable temperature of the sensitive plates, so as to ensure the distillation efficiency and product quality.